Emhlabeni wokuhlanzeka okuphelele nokwengamela kwenhlanzeko, i-ATP Luminometer yethu imi njengethuluzi loguquko ekuhlolweni kwe-microbial surface. Iphromothwa i-Kedun, inkampani edume ngezisombululo zayo ezintsha, le divayisi iyisibonelo solula, isivinini, nokunemba.I-ATP Luminometer evela e-Kedun ikunikeza okuhlangenwe nakho okungenakuqhathaniswa ekuqapheni ukusebenza kahle kokuhlanza nokunquma isimo sokuhlanzeka sendawo namanzi. Idizayinelwe ukuthi kube lula ukuyisebenzisa, leli thuluzi liyasebenziseka-linobungane njengoba liba khona, alibonisi izinkinga, ngisho nakulabo abangajwayele izinto zokusebenza. Okuyenza igqame, nokho, ukunemba kanye nemiphumela esheshayo eyivezayo, okuyenza ibe idivayisi-efunwayo endaweni yokuhlola indawo ehlala izinambuzane. Inzuzo eyinhloko yokusebenzisa i-ATP Luminometer ye-Kedun ilele emiphumeleni yayo esheshayo nenembayo. Lokhu kuqinisekisa ukuthi noma yikuphi ukungcola noma ukwephulwa kwenhlanzeko kungabanjwa ngesikhathi sangempela, ngaphandle kokulinda isikhathi eside ukuze uthole imiphumela yelebhu. Ngenxa yalokho, lokhu kukunikeza amandla okusebenzisa noma yiziphi izinyathelo zokulungisa ezidingekayo ngokushesha, uqinisekisa ukugcinwa kwamazinga enhlanzeko afanele ngaso sonke isikhathi. I-Flash-imiphumela esheshayo isho ukuthi akukho ukuyekethisa ekuhlanzekeni nenhlanzeko.

I-luminometer ye-Kedun ATP inikeza isixazululo esilula, esisheshayo nesinembile sokuqapha ukusebenza kahle kokuhlanza kanye nesimo sokuhlanzeka kwendawo namanzi. Ifakwe ngohlelo oluthuthukisiwe nesikrini esikhulu, iklanyelwe ukuthi isetshenziswe ngesandla esisodwa ukuze kube lula ukuyisebenzisa. Ngokusekelwe kumgomo we-firefly luminescence, i-luminometer ye-Kedun ATP isebenzisa uhlelo lwe-luciferase-luciferin ukuthola i-adenosine triphosphate (ATP).

Ukuboniswa kwemiphumela ethembekile Kumayunithi Okukhanya Okuhlobene (RLU) ku-Kedun ATP Luminometer. Ukusebenza kokuhlanza kuyaqashwa ukuze kuncishiswe ingozi yokungcoliswa kwesampula. Umphumela wesikhathi sangempela uboniswa esikrinini phakathi kwemizuzwana eyishumi. Ngaphezu kwalokho, iyatholakala ukuthi ifakwe ezinhlelweni zenkampani ze-HACCP ukuqapha ukusebenza kokuhlanza.

I-Kedun ATP fluorescence detector isetshenziswa kakhulu ekudleni, emithini nempilo, emithini, kumakhemikhali wansuku zonke, ukwenza iphepha, ukwelashwa kwamanzi ezimbonini, ukuvikela izwe, ukuvikelwa kwemvelo, ukuphathwa kwamanzi, ukungena kwentela- ukuphuma kwe-quarantine neminye iminyango yomthetho kanye nezinye izimboni.



Ukwengeza, i-ATP Luminometer iguquguquka ekusebenzeni kwayo. Ukusetshenziswa kwayo akukhawulelwe ekuhlolweni kwendawo kuphela, kodwa kudlulela nasemanzini. Ngakho-ke, usungakwazi manje ukuqinisekisa isimo senhlanzeko semithombo yakho yamanzi kanye nezindawo zakho ezibonakalayo. Nge-luminometer ye-Kedun's ATP, ukuhlolwa kwe-microbial surface sekuyisixazululo esiqinisekisa ukuhlanzeka. Empeleni, i-ATP Luminometer ye-Kedun ingaphezu nje kwethuluzi; kuyisixazululo. Isixazululo senkinga engapheli yokugcina inhlanzeko kanye nenhlanzeko ngendlela elula, esheshayo nenembile. Bopha amandla e-ATP Luminometer yethu futhi uchaze kabusha indlela yakho yokuhlola indawo ye-microbial.
FILTRA-BAG picture

Isici

Isixazululo esilula, esisheshayo nesinembile sokuqapha ukusebenza kahle kokuhlanza

Idizayinelwe ukuthi isetshenziswe ngesandla esisodwa ukuze kube lula ukuyisebenzisa

Umphumela wesikhathi sangempela uboniswa esikrinini phakathi kwamasekhondi angu-15

Ilula futhi iyaphatheka

Ukuzwela okuphezulu kwe-10-15 kuya ku-10-18 mol

Ulwazi lomsebenzisi luyahleleka

 

Ipharamitha

Ikati. Cha. I-KAL2301
Ubuningi 9,999 RLUs
Ukunemba 1 x 10-18 mol
Umphumela imizuzwana engu-15
Izinga lokutakula 90%- 110%
Ukugxambukela ± 5 RLUs
Izinga lokushisa lokusebenza 5°C - 40°C
Umswakama wokusebenza 20%-85%
Isimo sokulinda ngu-20 °C 180 izinsuku
I-Cable Interface I-USB
Shaja Ibhethri ye-lithium
Ubukhulu 188 x 77 x 37mm
 