Sterile Sampling Bags for Stomacher Blender Microbiology Applications
Discover the power and effectiveness of Kedun's Sterile Sampling Bags, specifically designed for the versatile applications within stomacher blender microbiology. Our sterile bags act as an essential tool in various domains such as microbiological testing, food safety analysis, and environmental testing. Crafted with meticulous precision, these sterile bags come with a commendable reputation of enhancing the efficiency and accuracy of stomacher blender microbiology functions. From the simplest to the most intricate tests, these bags are tailored to meet the diverse range of microbiological challenges ensuring error-free results. Their user-friendly nature combined with their high-quality build, makes them a popular choice for professionals.Kedun Sterile Sampling Bags are widely used as sample collection tool in these ranges of microbiological test, food safety and environment test. The applications vary from general blending purposes to samples preparation for analysis testing.
Kedun sterile sampling bags are made from high quality polyethylene. Manufactured in Class 100,000 clean room facility, the standard manufacturing procedure eliminates all external sources of contamination.
There are two white tapes are fixed at sides of the top of bag. Tapes are puncture proof to prevent damaging hands from wires inside. The two wires sealed by tapes facilitate mouth shape when users pull the middle of tapes to open bag. In addition, one perforated line is designed at top of bag to tear off bag easily. It is recommended to fold tapes three times after collecting samples into bags for better sealing.
There is a white area printed on bag for users to marking information. White marking area on sterile sampling bag is optional. For holding big amount of samples, flat wire is designed to help stabilizing large capacity bags, for instance 55 oz bag and 100 oz bag.
All Kedun sterile sampling bags are sterilized and DNase-free, RNase-free, Pyrogen free.
Food safety is a pressing concern in today's world and Kedun's Sterile Sampling Bags are poised to make a significant contribution in this area. They are often used for obtaining flawless samples, which are then tested meticulously in stomacher blenders to glean valuable insights about the quality of food. Additionally, they are equally proficient in carrying out rigorous environment tests, providing reliable data that is crucial for maintaining environmental health. By engaging our sterile sampling bags in your stomacher blender microbiology operations, you can expect to streamline your workflows while maintaining the integrity of your test specimens. With Kedun's Sterile Sampling Bags, experience the perfect blend of functionality and simplicity for your stomacher blender microbiology needs. Embrace precision, embrace efficiency, embrace Kedun.

Feature
1. Made from high quality polyethylene
2. Leaking proof and airtight
3. Tapes are puncture proof to prevent damaging hands from wires inside
4. One perforated line is designed at the top of bag to tear off bag easily
5. Using temperature range is from - 210°C to 82 °C
6. White marking area and flat wire types are optional
7. Sterile, DNase-free, RNase-free, Pyrogen free
Two round wires
| Cat. No. | oz | ml | mm | um | marking | wires | /box | Outer ctn |
| K127076AA70X | 2 | 60 | 127 x 76 | 70 | No | round | 500 | 1000 |
| K127076AA70Y | 2 | 60 | 127 x 76 | 70 | Yes | round | 500 | 1000 |
| K178076AA70X | 4 | 120 | 178 x 76 | 70 | No | round | 500 | 1000 |
| K178076AA70Y | 4 | 120 | 178 x 76 | 70 | Yes | round | 500 | 1000 |
| K229114AA70X | 18 | 540 | 229 x 114 | 70 | No | round | 500 | 1000 |
| K229114AA70Y | 18 | 540 | 229 x 114 | 70 | Yes | round | 500 | 1000 |
| K304114AA70X | 27 | 810 | 304 x 114 | 70 | No | round | 500 | 1000n |
| K304114AA70Y | 27 | 810 | 304 x 114 | 70 | Yes | round | 500 | 1000 |
| K381114AA70X | 36 | 1080 | 381 x 114 | 70 | No | round | 500 | 1000 |
| K381114AA70Y | 36 | 1080 | 381 x 114 | 70 | Yes | round | 500 | 1000n |
| K229140AA90X | 24 | 720 | 229 x 140 | 90 | No | round | 500 | 1000n |
| K229140AA90Y | 24 | 720 | 229 x 140 | 90 | Yes | round | 500 | 1000 |
| K381140AA90X | 42 | 1260 | 381 x 140 | 90 | No | round | 500 | 1000 |
| K381140AA90Y | 42 | 1260 | 381 x 140 | 90 | Yes | round | 500 | 1000 |
| K300180AA100X | 55 | 1650 | 300 x 180 | 100 | No | round | 250 | 1000 |
| K300180AA100Y | 55 | 1650 | 300 x 180 | 100 | Yes | round | 250 | 1000 |
One round wire + one flat wire
| Cat. No. | oz | ml | nm | um | marking | wires | /box | Outer ctn |
| K229114AB70X | 18 | 540 | 229 x 114 | 70 | No | round + flat | 500 | 1000 |
| K229114AB70Y | 18 | 540 | 229 x 114 | 70 | Yes | round + flat | 500 | 1000 |
| K229140AB90X | 24 | 720 | 229 x 140 | 90 | No | round + flat | 500 | 1000 |
| K229140AB90Y | 24 | 720 | 229 x 140 | 90 | Yes | round + flat | 500 | 1000 |
| K381140AB90X | 42 | 1260 | 381 x 140 | 90 | No | round + flat | 500 | 1000 |
| K381140AB90Y | 42 | 1260 | 381 x 140 | 90 | Yes | round + flat | 500 | 1000 |
| K300180AB100X | 55 | 1650 | 381 x 140 | 100 | No | round + flat | 250 | 1000 |
| K300180AB100Y | 55 | 1650 | 381 x 140 | 100 | Yes | round + flat | 250 | 1000 |
| K254254AB100X | 60 | 1800 | 254 x 254 | 100 | No | round + flat | 250 | 1000 |
| K254254AB100Y | 60 | 1800 | 254 x 254 | 100 | Yes | round + flat | 250 | 1000 |
| K356254AB100X | 100 | 3000 | 356 x 254 | 100 | No | round + flat | 250 | 1000 |
| K356254AB100Y | 100 | 3000 | 356 x 254 | 100 | Yes | round + flat | 250 | 1000 |
Two flat wires
| Cat. No. | oz | ml | mm | um | marking | wires | /ctn |
| K356305BB100X | 106 | 3180 | 356 x 305 | 100 | No | flat | 250 |
| K406305BB100X | 118 | 3540 | 406 x 305 | 100 | No | flat | 250 |
| K457305BB100X | 132 | 3960 | 457 x 305 | 100 | No | flat | 250 |
| K508305BB100X | 148 | 4440 | 508 x 305 | 100 | No | flat | 250 |
| K508381BB100X | 184 | 5520 | 508 x 381 | 100 | No | flat | 100 |
| K610381BB100X | 220 | 6600 | 610 x 381 | 100 | No | flat | 100 |